Effect of Electromigration (ksi != 0)
Free Moving Boundary Condition: This BC assumes that there is no direct contact with electrode pads at the cathode and/or anode edges. The whole interconnect test
piece rests on a substrate (TiN or Mo, W), which has very high specific resistivity compared to the interconnect material.